Round Face high accuracy +-0.5C digital food thermometer probe thermometer with cover
Measuring Range
|
-40°C-300°C/ -50°F-572°F
|
Accuracy
|
±0.5°C (-10°C to 100°C), ± 1.0°C(-20°C to -10°C)(100°C to 150°C), otherwize ± 2°C
|
Resolution
|
0.1°F(0.1°C)
|
name
|
high quality customized smart wireless meat thermometer instant read meat thermometer cooking
|
Probe
|
150/300/1500mm 304 stainless steel
|
Battery
|
CR2032*2 Button(1500 hours), pre-installed
|
Waterproof
|
IP68
|
Alarm function
|
High/Low temperature alarm at preset temperature
|
Calibration function
|
Can be easily calibrated at home
|
Other function
|
Auto power off function, Backlight function, Max/Min memory
|
More features
|
Magnet on the back, Handheld, sitting and hanging
|
Turn on the device:
Press the on/off button you can turn on the device!
Turn off the device:
Press the on/off and hold 4 seconds, then you can shutdown the thermometer!
Replace the battery:
1. Use a small, thin coin to open the battery door from the thermometer. Insert the coin in the slot on top of the battery door and turn it counter-clockwise till the small triangle feature on top of the battery door is lined up with the "Un-lock" symbol.
2. Take out the door and replace the battery, make sure the original o-ring is inside the battery chamber, line up the small line feature on top of the battery door with the "Un-lock" symbol, then insert the battery door into the chamber and turn it clockwise till the small line feature on top of the battery door is lined up with the "Lock" symbol.
Calibration procedures:
1. Making a proper ice bath is all about keeping a proper ice-water ratio, fill the vessel all the way to the top with ice. Crushed ice is preferred because there are fewer gaps between the ice. However cubed ice will also work fine.
2. Slowly add cold water to fill the spaces between the ice, fill to about 1/3 below the top of the ice, let the mixture sit for a minute or two to allow the temperature of the water to settle. If you see the ice starting to float off the bottom of the vessel, pour off some water and add more ice. Water below the ice will not be at 0ºC.
3. Once the mixtures has rested for a minute or two, insert your thermometer probe, place probe tip in center of cup, making sure tip is fully submerged but not in contact with the cup surface, stir for a minimum of 5 seconds.
4. Keep probe tip completely submerged, press and hold "CAL" button for 2 seconds until "CAL" appears on the LCD display, then release.
5. Calibration is complete when display automatically returns to normal operation mode