Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)

Product Details
Customization: Available
Standard: Celsius/Fahrenheit
Accuracy: ≤0.5°C
Still deciding? Get samples of US$ 10/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
24
Year of Establishment
2013-12-06
  • Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)
  • Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)
  • Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)
  • Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)
Find Similar Products

Basic Info.

Model NO.
TZ-05
Temperature Alarm
2-8
Weight
23G
Communication Interface
USB2.0
Resolution
0.1 ºC
Function
for Cold Chain Transportation (Tz-05)
Name
Single-Use Pdf Temperature Data Logger
Transport Package
Color Box
Specification
67mm*28mm*5.5mm
Trademark
wenmeice
Origin
China
HS Code
9025199090
Production Capacity
10000PCS/Day

Product Description

Single-use PDF Temperature Data Logger for cold chain transportation (TZ-05)

Product Description:

Single-use PDF Temperature Data Logger(TempU05)is one kind of cold chaindata logger. It is mainly used for temperature recording during storage and transportation of foodstuff, medicine, chemicals and other products. After record finishing, it can be inserted to computer's USB port and get PDF report directly
Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)



Data :
Status Action LED Indication
Inactivated Click once the buttonto judge if the logger is inactivated. ALARM and OK lights flash once at the same time, means the logger is inactivated.
Activated The LED will flash every 10s automatically. If "OK" light flashes, the logged temperature has never been out of range. If "ALARM" light flashes, the logged temperature data was out of range before.
Stopped No press the button Both ALARM and OK lights won't flash
Short press the button OK light flash (normal temperature)
ALARM light flash (temperature data was out of range)
       
 
Start/Stop LED Indication Note
Before start, press button and hold more than 3s OK light bright for 3s Start data logger
After start, press button and hold more than 3s ALARM light bright for 3s Stop data logger


Product Features:

  • Use Type: Single-use
  • Log Interval:10mins (60days)
  • Accuracy: ±0.5ºC (-20ºC~+40ºC); ±1ºC(others)
  • Data Storage Capacity: 10000 records
  • Alarm Temperature: <2ºC or >8ºC (<35.6ºF or >46.4ºF)
  • Start Delay: 30mins
  • Operating Temperature: -30ºC~+60ºC (22ºF~140ºF)
  • Storage: Recommend 20% to 60% RH, 10ºCto 50ºC
  • Water Proof Level: IP67
  • Dimension: 67mm*28mm*5.5mm
  • Communication Interface: USB2.0
  • Report Type: PDF
  • Software: No need install any software

       
        Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)

      

Operating Instructions :

  1. Press and hold the button more than 3s. Then the "OK" light will brighten for 3s, which indicates a successful starting, then you can put the data logger where you want to monitor and record.
  2. When logging, the "OK" LED will flash in green every 10s, if there are no alarm events happened. Or the "ALARM" LED will flash in red every 10s, if there  happenedalarm events.
  3. When the memory is full or press and hold the button for more than 3s, the "ALARM" light will brighten for 3s, which indicates a successful stopping.
  4. Tear or cut off the plastic bag and insert the logger into an available USB port on a PC. "OK" light and "ALARM" light will flash in turn when a PDF report is generating. When the PDF report has been generated, the"OK"light will brighten until pulling out from the USB port. (Note: If the logger is stopped during the status of start delay, there will be a PDF report but no data.)

          Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)

 

Note:

  1. Make sure the data logger has been started before place it into the environment to use.
  2. Don't place the data logger directly into the corrosive liquid.
  3. Please do not operate our data logger under the bright light, because under the bright light, LED flashing will be difficult to be observed.
  4. Please no direct heating or micro-wave heating or charge the battery.
  5. Please recycle or dispose the data logger in accordance with local laws and regulations.

 

Application:
The device is mainly used to monitor the temperature of food, medicine, chemical and other products during storage and transportation.It is widely used in all links of warehousing and cold chain logistics, such as reefer containers, refrigerated trucks, refrigerated distribution boxes, cold storage laboratory, etc.Compact, light and economical to use.

Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)
Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)


Packing information:

Packaging for brew thermometer
Individual packging:White box
Carton size:46x48x46cm
50pcs/ctn
Gross weight:15kg
Net weight:13kg

Shipping:


Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)
Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)

Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)


Certificates:

Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)
Our clients and colleague:
Single-Use Pdf Temperature Data Logger for Cold Chain Transportation (TZ-05)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier