Digital Multimeter Auto Rang Multimeter Unit With Multimeter Cable
Parameter
Maximum voltage between input and the ground |
CAT III 600V |
Fuse |
F1 250mA/600V F2 10A/600V |
Power |
9V battery, NEDA 1604 or 6F22 |
Maximum display value |
1999 |
Over-range indication |
"OL" |
Polarity display |
"-"for negative polarity |
Operating temperature |
0OC to 40OC |
Storage temperature |
-10OC to 50OC |
Low voltage indication |
battery condition on the display |
Appearance dimension |
138mm X 69mm X 31mm |
Weight |
170g |
Direct current voltage measurement
Range |
Resolution |
Accuracy |
200mV |
100uV |
+0.5% of reading.±3 digits |
2V |
1mV |
+0.5% of reading,±3 digits |
20V |
10mV |
+0.5% of reading,±3 digits |
200V |
100mV |
+0.5% of reading,±3 digits |
600V |
1V |
+0.8% of reading,±5 digits |
Overload Protection: 200mV range:600V dc or rms;
The rest ranges:600V dc or rms
Direct current measurement
Range |
Resolution |
Accuracy |
20A |
0.01μA |
+1% of reading,±3 digits |
200uA |
0.1uA |
+1% of reading,±3 digits |
2mA |
1A |
+1% of reading,±3 digits |
20mA |
10uA |
+1% of reading.±5 digits |
200mA |
100A |
±1.5% of reading,±5 digits |
10A |
10mA |
+3% of reading, ±10 digits |
Overload Protection: F1 250mA/600V fuse F2 10A/600V
Meter with temperature function no 20μA
Alternating voltage measurement
Range |
Resolution |
Accuracy |
200V |
100mV |
±1.2 % of reading,±10 digits |
600V |
1V |
+1.2 % of reading.±10 digits |
Overload Protection: 600V dc or rms
Frequency range: 40Hz to 400Hz
Display:Averae(effective value of sinusoid)
Resistor
Range |
Resolution |
Accuracy |
200Ω |
0.1Ω |
+0.8% of reading,±5 digits |
2KΩ |
1Ω |
+0.8% of reading,±2 digits |
20KΩ |
10Ω |
+0.8% of reading,±2 digits |
200KΩ |
100Ω |
+0.8% of reading,±2 digits |
2MΩ |
1KΩ |
±1.0% of reading .±5 digits |
Maximum open circuit voltage: 3.2V
Overload protection: 600V DC or RMS
Diode and circuit on-off measurement
Range |
Description |
|
When the on-resistance is smaller than (70±30)Ω the built-in buzzer will beep. |
|
Displays the approximate diode positive voltage. |
Overload protection: 600V DC or RMS. AC.
Temperature measurement
Range |
Resolution |
Measurement |
Accuracy |
OC |
1OC |
-20OC to 0OC -0OC to 400OC . 400OC to 1000OC |
±10%Range, ±2 digits ±1.0%Range, ±3 digits ±2.0%Range |