Operating Instruction:
1. Press and hold the button more than 3s. Then the "OK" light will brighten for 3s, which indicates a successful starting, then you can put the data logger where you want to monitor and record.
2. When logging, the "OK" LED will flash in green every 10s, if there are no alarm events happened. Or the "ALARM" LED will flash in red every 10s, if there happened alarm events.
3. When the memory is full or press and hold the button for more than 3s, the "ALARM" light will brighten for 3s, which indicates a successful stopping.
4. Tear or cut off the plastic bag and insert the logger into an available USB port on a PC. "OK" light and "ALARM" light will flash in turn when a PDF report is generating. When the PDF report has been generated, the "OK" light will brighten until pulling out from the USB port. (Note: If the logger is stopped during the status of start delay, there will be a PDF report but no data.)
Specification:
Ø Use Type: Single-use
Ø Log Interval: 10mins (60days)
Ø Accuracy: ±0.5ºC (-20ºC~+40ºC); ±1ºC(others)
Ø Data Storage Capacity: 10000 records
Ø Alarm Temperature: <2ºC or >8ºC (<35.6ºF or >46.4ºF)
Ø Start Delay: 30mins
Ø Operating Temperature: -30ºC~+60ºC (22ºF~140ºF)
Ø Storage: Recommend 20% to 60% RH, 10ºC to 50ºC
Ø Water Proof Level: IP67
Ø Dimension: 67mm*28mm*5.5mm
Ø Communication Interface: USB2.0
Ø Report Type: PDF
Ø Software: No need install any software
Operation Indication:
Status |
Action |
LED Indication |
|
Inactivated |
Click once the button to judge if the logger is inactivated. |
ALARM and OK lights flash once at the same time, means the logger is inactivated. |
|
Activated |
The LED will flash every 10s automatically. If "OK" light flashes, the logged temperature has never been out of range. If "ALARM" light flashes, the logged temperature data was out of range before. |
||
Stopped |
No press the button |
Both ALARM and OK lights won't flash |
|
Short press the button |
OK light flash (normal temperature) |
||
ALARM light flash (temperature data was out of range) |
Start/Stop |
LED Indication |
Note |
Before start, press button and hold more than 3s |
OK light bright for 3s |
Start data logger |
After start, press button and hold more than 3s |
ALARM light bright for 3s |
Stop data logger |