Product name:
|
TempU 03 Multi-use LCD Display Temp & RH Data Logger For Logistics Monitoring
|
Temperature unit:
|
ºC or ° F
|
Measuring Range:
|
Humidity 0%~100%RH, Temp -30 ºC~60 ºC
|
Accuracy:
|
±3%RH; ±0.5 ºC(-20 ºC~+40 ºC), ±1.0 ºC(other)
|
Resolution :
|
0.1%RH typically, 0.1 ºC
|
Memory Capacity:
|
32000 readings
|
Record Interval:
|
10 seconds to 18 hours adjustable [Default:10 mins]
|
Report Generation:
|
Simultaneously generate PDF report and CSV files
|
Communication Interface: |
USB2.0
|
Product Weight:
|
25g
|
Dimensions:
|
89mm*36mm*16mm
|
Battery:
|
Typically 1 Year; CR2032 3.0V Lithium Battery (Depending on Sampling Rate and Environment)
|
a. Start Recording
Press and hold the " " button for more than 3S until the " OK" light is on, and the " " or "WAIT" displays on the screen,indicating starting recording successfully.
b. Mark
When the device is in the recording status, press and hold the " " button for more than 3S, and the screen will switch to the "MARK" interface. The number of "MARK" will increase by one, indicating data was marked successfully.
(Note : One record interval only can mark one time ,the logger can mark 6 times in one recording trip. Under status of start delay, the mark operation is disabled. )
c. Stop Recording
Press and hold the " " button for more than 3S until the "ALARM" light is on, and the " "displays on the screen, indicating stopping recording successfully.
Note :If the logger is stopped during the status of start delay, there will be a PDF report but no data.